27
Ordering information
LT544DLITE United States, 85 V ac to
265 V ac, 50/60 Hz
LT544DLITE-EUR Europe, 85 V ac to
265 V ac, 50/60 Hz
LT544DLITE-AUS Australia, 85 V ac to
265 V ac, 50/60 Hz
LT544DLITE-ISR Israel, 85 V ac to
265 V ac, 50/60 Hz
LT544DLITE-ITL Italy, 85 V ac to 265 V
ac, 50/60 Hz
LT544DLITE-SWS Switzerland, 85 V ac
to 265 V ac, 50/60 Hz
LT544DLITE-1520 United Kingdom,
85 V ac to 265 V ac, 50/60 Hz ,15-Amp
NEMA power plug with 20-Amp female
power connector
LT544DLITE-2020 85 V ac to 265 V ac,
50/60Hz, 20-Amp NEMA power plug
with 20-Amp female power connector
LT544DLITE-230V 85 V ac to 265 V ac,
50/60 Hz, with 230 V ac North America
power plug and female power connector
Included accessories
600/100FG Chassis Cable, coil cord,
8 ft extended
600/101FG Chassis Cable, coil cord,
16 ft extended
600/102FG Chassis Ground Probe, 8 ft
coil cord
600/600FG Soft Carrying Case (6 in x
10 in x 4 in)
600/200FG External Leakage Cable,
coil cord, 8 ft extended
600/201 External Leakage Cable, coil
cord, 16 ft extended
600/206 Universal Ultrasound Probe
Tester
Key features
• Small, lightweight, self-con-
tained portable instrument
• Universal power supply—
input voltage from 85 V ac to
265 V ac
• Chassis resistance mea-
surements are made with a
four-wire Kelvin bridge to
eliminate errors due to cable
length
• Test method complies with
AAMI load per ANSI/AAMI
ES1-1993
• Leakage current can be mea-
sured in Open/Closed Neutral,
Normal/Reversed Polarity and
Open/Closed Ground
• All Leakage current measure-
ments are displayed directly
in µA
This device is designed
to perform simple
electrical safety tests
on any type of medical
equipment, whenever
patient lead testing is
not required.
The rugged, hand-
held instrument is built
for quick and easy use.
A simple selector knob
controls the functions:
Leakage Current and
Chassis Resistance.
Accurate test measurements are shown on the large display.
Heavy-duty switches change polarity, open and close the neutral and
select Chassis or Earth Leakage Current measurements. A four-wire Kelvin
bridge eliminates reading errors in resistance due to cable length and
contact resistance. True-rms measurements are provided for all current
readings. The AAMI test load is utilized.
Ground resistance
Range
0 Ω to 19.99 Ω
Accuracy ± 1% R, ± 1 LSD
Resolution
10 mΩ
Leakage current
Range 0 µA to 1, 999 µA
Accuracy DC and 25 Hz to 1kHz: ± 1 % of reading, ± 3 LSD
1.0 KHz to 100 KHz: ± 2.5 % of reading, ± 3 LSD
100 KHz to 1 MHz: ± 5 % of reading, ± 3 LSD
Current capacity
LT544DLite- 1515 15 A at 120 V ac
LT544DLite- 230 V 10 A at 230 V ac
LT544DLite- 1520/2020 20 A, at 230 V ac, 20 % duty cycle (2 minutes on, 8 minutes off)
Controls 1. Function switch – 4 position rotary
2. Neutral switch – 2 position rocker (Open/Closed)
3. Polarity switch – 3 position rocker (Normal/Off/Reversed)
4. Leakage switch – 2 position rocker (Chassis/Earth)
DUT power 85 V ac to 265 V ac, 16 A @ 120 V, 10 A @ 230 V
Physical size 90 mm x 180 mm x 38 mm (3.5 in x 6.2 in x 1.6 in)
LT544DLITE
Digital Safety Tester
Specications
Electrical Safety Analyzers