8
Ordering information
Impulse 6000D Defibrillator
Analyzer
IMPULSE 6000D United States, 120 V
IMPULSE 6000D-01 Schuko
IMPULSE 6000D-02 United Kingdom
IMPULSE 6000D-03 Japan
IMPULSE 6000D-04 Australia
IMPULSE 6000D-05 India
IMPULSE 6000D-06 Brazil
Impulse 7000DP Defibrillator/
Transcutaneous Pacemaker Analyzer
IMPULSE 7000DP United States, 120 V
IMPULSE 7000DP-01 Schuko
IMPULSE 7000DP-02 United Kingdom
IMPULSE 7000DP-03 Japan
IMPULSE 7000DP-04 Australia
IMPULSE 7000DP-05 India
IMPULSE 7000DP-06 Brazil
Impulse 7000DP Defibrillator/
Transcutaneous Pacemaker Analyzer
with test automation
TA-IMP7KDP United States, 120 V
TA-IMP7KDP-01 Schuko
TA-IMP7KDP-02 United Kingdom
TA-IMP7KDP-03 Japan
TA-IMP7KDP-04 Australia
TA-IMP7KDP-05 India
TA-IMP7KDP-06 Brazil
Impulse 7000DP Defibrillator/
Transcutaneous Pacemaker Analyzer
with Impulse 7010 and test
automation
TA-IMP7K/7010US United States,
120 V
TA-IMP7K/7010SHK Schuko
TA-IMP7K/7010UK United Kingdom
TA-IMP7K/7010JPN Japan
TA-IMP7K/7010AUS Australia
TA-IMP7K/7010BRA Brazil
Included accessories
CD-ROM Users Manual CD
MANUAL Getting Started Guide
Battery Eliminator (country specific)
SOFT CASE Carrying Case
FBC-IMP7000-8003 Defibrillator
Paddle Contact Plates
CABLE ASSEMBLY USB Computer
Communication Cable
Impulse 7010 Defibrillator Selectable Load Accessory
Maximum voltage 5000 V
Maximum continuous power 12 W, equivalent to 10 defib pulses of 360 J every 5 minutes
Inductance
< 2 µH, @25 Ω
< 3 µH, @50 Ω
< 4 µH, @75 Ω and 100 Ω
< 5 µH, @125 Ω
< 6 µH, @150 Ω
< 7 µH, @175 Ω
< 8 µH, @200 Ω
Temperature Operating: 10 °C to 40 °C (50 °F to 104 °F)
Storage: -20 °C to 60 °C (-4 °F to 140 °F)
Humidity 10 % to 90 % non-condensing
Dimensions (WxDxH) 154 mm x 272 mm x 138.7 mm (6.07 in x 10.71 in x 5.46 in)
Weight (net) 1.54 kg (3 lb 6.2 oz)
Safety class Complies with EN61010-1 2nd Edition, Class II product
Safety standards CE: IEC/EN61010-1 2nd Edition; Pollution degree 2;
CSA: CAN/CSA-C22.2 NO,61010-1, UL61010-1; C-Tick:
Australian EMC
Warranty Two-year extended warranty (no-cost extended warranty
available after first-year calibration at any Fluke Biomedical
authorized service center)
Calibration interval One-year
Electrical specifications (for load accessory and analyzer together)
Load settings
25 Ω, 50 Ω, 75 Ω, 100 Ω, 125 Ω, 150 Ω, 175 Ω, and 200 Ω
± 1 %
Accuracy Energy (all except pulsed biphasic): 2 % of reading + 0.1 J
with 25 Ω, 75 Ω though 200 Ω loads, 1 % of reading + 0.1 J
with 50 Ω load
Energy (pulsed biphasic): 2.5 % of reading + 0.3 J with 25
Ω, 75 Ω though 200 Ω loads, 1.5 % of reading + 0.3 J with
50 Ω load
Voltage: 1 % of reading + 2 V with 25 Ω and 50 Ω loads, 2 %
of reading + 2 V with 75 Ω through 200 Ω loads
Current: 2 % of reading + 0.1 A with 25 Ω load, 1 % of
reading + 0.1 A with 50 Ω through 200 Ω loads
Discharge curve at 175 Ohms using Ansur and the 7010 load box. Note the
differences in the shape, the peak currents and the time of the discharges.
Impulse 6000D/7000DP
Debrillator/Transcutaneous Pacemaker Analyzer
Specications
Defibrillator/Transcutaneous Pacer Analyzers
riešenia na presné meranie
http://www.elso.sk
Vista de página 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 67 68

Comentários a estes Manuais

Sem comentários