Dynatech MP-7000 Especificações Página 5

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 68
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 4
5
The Impulse 6000D Defibrillator Analyzer and Impulse 7000DP
Defibrillator/Transcutaneous Pacemaker Analyzer Test Systems are rugged,
portable precision test instruments that ensure proper operation and ulti-
mate performance of critical life-support cardiac-resuscitation equipment.
The Impulse 6000D and Impulse 7000DP test capabilities encompass the
spectrum of worldwide-established pulse shapes, showcase breakthrough
AED technology compatibility, and outperform in accuracy and standards.
Additionally, the Impulse 7000DP incorporates the tests and the extensive
range of test loads and measurement algorithms needed to test external
transcutaneous pacemakers.
In conjuntion with an Impulse 7000DP, the Impulse 7010 Defibrillator
Selectable Load Accessory provides multiple loads of 25 Ω, 50 Ω, 75 Ω,
100 Ω, 125 Ω, 150 Ω, 175 Ω, and 200 Ω for defibrillator performance
testing. A standard USB interface enables computer control and data
transfer, and optional Ansur PC-based automation software increases pro-
ductivity by outfitting users with an easy-to-use method to standardize
testing procedures and capture, print and document data.
Model QED 6 Impulse 6000D Impulse 7000DP
Monophasic and dc
biphasic energy capability
Yes Yes Yes
Pulsed biphasic engery
capability
No Yes Yes
Defibrillator tests Output energy Output energy Output energy
Cardioversion Cardioversion Cardioversion
Peak measurements Max energy/
charge-time overshoot
Max energy/
charge-time overshoot
Peak and average
current
Peak and average
current
Voltage measurement Voltage measurement
Normal ECG/performance
waves
No Yes Yes
Transcutaneous pacer tests No No Yes
Key features
Impulse 7010 Defibrillator
Selectable Load Accessory
provides multiple loads of 25 Ω,
50 Ω, 75 Ω, 100 Ω, 125 Ω,
150 Ω, 175 Ω, and 200 Ω to
comply with IEC 60601-2-4
standard (optional)
Lown, Edmark, trapezoidal,
biphasic and pulsed bipha-
sic defibrillation technology
compatibility
AED technology compatibility
First-class measurement
accuracy: ± 1 % of reading
0.1 J
Intuitive user interface and
backlight, easy-to-ready
display
Portable, rugged, easy to carry
Long-lasting, rechargeable
battery
Internal pacer brand selections
Pacer input protected against
defibrillator output (7000DP
only)
10 isolated ECG electrodes that
provide 12 combinations for
standardized clinical signals
Flexible heart-rate settings
(1 BPM step) facilitate rate
meter accuracy and alarm
testing
DSP-based measurements
enable future firmware and
waveforms upgrade
Unique integrated posts for
secure connections
Optional Ansur test automation
software to standardize testing
procedures, capture waveforms,
and print and document test
result
Impulse 6000D/7000DP
Debrillator/Transcutaneous Pacemaker Analyzer
Product comparison chart
Defibrillator/Transcutaneous Pacer Analyzers
Note: AC pulsed biphasic waveform has not been approved in the United States.
riešenia na presné meranie
http://www.elso.sk
Vista de página 4
1 2 3 4 5 6 7 8 9 10 ... 67 68

Comentários a estes Manuais

Sem comentários